TTransformer Oil Regeneration Plant

Application

Transformer Oil Regeneration Plant is used to regenerate transformer oil to improve its acid value, Interfacial Tension, other than the Dielectric Strength, water content, dissolve gas content and solid particle.

After the process of regeneration, the oil is able to return to all parameter of new oil.

One of our system advantages are our refining medium can be reactivated 300 times for continue usage. It is environmentally friendly compare to old fuller earth technology. User can save tremendous expenses in replacing, disposing refining medium and zero down time.

Our system is also able to perform desludging process at the life transformer, this process is to remove the sludge from the transformer coil and inner parts, during the regeneration process.

The transformer will be return to tip top condition after the regeneration process.

We provide various capacities to cater for all sizes of transformer requirement.

Description Untreated Oil Treated Oil
Dielectric Strength <30kV >70kV
Water content 50 ppm < 5 ppm
Gas content Up to 10% < 0.1%
Acidity 0.25 mg KOH/g < 0.03 mg KOH/g
IFT < 15 Dynes / cm > 35 Dynes / cm

Technical Results

Through on-site, on-line regeneration and desludging of the oil, the following results are achieved:

  • The moisture in the oil is reduced to below 10 ppm.
  • The acidity is reduced to less than 0.01 mg KOH/g oil.
  • The dielectric strength is improved to better than 60 - 70 kV
  • The IFT (Interfacial tension) is improved to up to 40 Dynes.
  • The Tan Delta (loss tangent) of the oil is improved to equal or less than 0.001.
  • Sludges dissolved or in suspension in the oil as well as sludge deposits are removed.
  • Particulate removal to 1 micron is achieved.
  • The oxidation stability of the oil restored to equal that of new oil.
  • The colour of the oil is restored.
  • The dielectric strength of the solid insulation is improved.
  • Degradation of the solid insulation has been halted.

Picture of Visible Change in Colour at Transformer

Oil Exchange On Site Regeneration
Off-line only. On or off-line by choice.
Used oil must be drained and transported to regen facility. Used oil regenerated in the transformer on-site, i.e. no removal or transportation costs.
Cost of new oil required for flushing. No new oil required.
Flushing is not very effective in that it reaches only approximately 10% of the interior surface if done through an inspection hole. If the top lid is removed, only approximately 60% of the interior surface could be reached. Cooling fins are difficult to flush. Approximately 20% of the contaminated oil remains trapped in the cellulose insulation. Regeneration dose more than restore the oil to its original, new condition. It also dissolves and removes the deposited sludges on the core and coils, in the cooling fins and ducts and in between windings. The adsorbed sludge (decay products) in the cellulose insulation is also removed.
The film of old oil remaining in the transformer and cellulose insulation contains polar compounds and can ruin large quantities of new oil. No decay products are left. The transformer is purged of contaminants that could not be removed by any.
Vacuum needs to be drawn on the transformer before retro filling. No vacuum drawing costs.
Danger of spillage in oil handling and transport. No spillage danger through handling of oil.
Downtime estimated between 8 and 36 hours depending on the size of transformer, revenue loss. No downtime with on-line regeneration, no revenue loss.
<

Enlightened Summit Sdn Bhd (ES)

199901018865 (493765-W)

Address: No.11, Jalan Makyong 5A/KU5, Bandar Bukit Raja, 41050 Klang, Selangor Darul Ehsan, Malaysia

+(60)3 - 3343 6181
+(60)3 - 3358 6181

+(60)3 - 3343 9228

info@esummitsb.com